Cold-Formed Structural Members Section Properties

Section Depth (in.) Flange Width (in.) Thickness (in.) Sx* (in.3) Ix* (in.4) Va* (kips) Ma* (in.-kips)
8z060 8.0 2.50 0.060 1.91 8.44 2.40 62.8
8z076 8.0 2.50 0.076 2.56 10.66 4.90 84.72
8z105 8.0 2.50 0.105 3.67 14.67 12.33 120.80
10z076 10.0 2.50 0.076 3.50 18.12 3.87 115.42
10z105 10.0 2.50 0.105 5.00 24.99 10.27 164.60
8c060 8.0 2.75 0.060 1.75 8.39 2.40 57.72
8c076 8.0 2.75 0.076 2.30 10.58 4.90 75.77
8c105 8.0 2.75 0.105 3.55 14.47 12.33 117.11
10c076 10.0 2.75 0.076 3.12 17.94 3.87 103.08
10c105 10.0 2.75 0.105 4.83 24.61 10.27 159.38

*Incorporation of section properties to a particular design must be done by a competent engineering professional who is cognizant of all criteria set forth by the latest edition of AISI.